Cool thermo unit CTU-Neo
Applicable to isothermal gene amplification by programming. Rapid and accurate programmable temperature control. Convenient, interchangeable well plate sizes.
Applications
●Various enzyme reaction and heat denaturation DNA/RNA
●Ligation of DNA [CTU-Mini]
●Gene amplification by LAMP method, whole gene amplification and so on
Features
Large enough size for half block x 2 or full block x 1
It can have one of full block which can have 40 x 1.5ml micro tubes. It also can have two of Half block which is common use with Mini and can use two types of container.
Various exchanging block containers
We have a several half blocks (option) to meet with various containers. Full block for 0.2ml micro tube can have PCR plate as well. For detail please see below.
Two types with different temperature range, Cooling type adopts Peltier system
There are DTU-Mini which is usable from Room temperature +3ºC, CTU-Mini which can handle low temperature by cooling with environmental friendly and energy saving Peltier heating and cooling system. Unique and improved temperature transition velocity.
Temperature programming with wait function
Wait function, stop watch timer counts until temperature reach to the set value. Together with improved temperature transition velocity, it can perform accurate temperature change at isothermal gene amplification.
Specifications
Model | CTU-Neo |
---|---|
Temperature Range | 0ºC – +105 ºC |
Temp. Control Accuracy | ±0.1ºC – +0.2 ºC |
Temperature transition time (environmental temperature: +25 ºC) | 37ºC –> 100ºC/ about 20min (when using B-1140) 37ºC –> 4ºC/ about 20min (when using B-1140) |
Minimum temperature setting unit | 0.1 ºC |
Temperature setting | Up and down setting |
Temperature Display | Digital display (setting temperature and current temperature) |
Heating-Cooling System | Heating and cooling by Peltier device |
Programming Function | 2memory, 9 segment, wait function, setting time: 0 – 99hrs 59min |
Safety device / function | Fuse, overvoltage protection, over current protection, overheat, sensor error, nonvolatile memory error, protection of sample (high/low temperature), high temperature cutout |
Dimensions | 210 x 268 x 175Hmm |
Weight | Approx. 4kg (exclude block) |
Power Supply | AC100V 2A |
Standard Accessory | Hook handle for taking block out |
●With open cover and environment over +30ºC, sometimes specifications doesn’t meet. |
Dimensions
Accessories
Half block for Microtube | B-0648
Aluminum block for DTU/CTU-Mini/Neo (micro tube 0.2ml x 48)
■Applicable Container / Number:micro tube 0.2ml x …
Half block for Microtube | B-0835
Aluminum block for DTU/CTU-Mini/Neo (micro tube 0.5ml x 35)
■Applicable Container / Number:micro tube 0.5ml x …
Half block for Microtube | B-1515
Aluminum block for DTU/CTU-Mini/Neo (micro tube 5.0ml×6pcs + 1.5ml×8pcs)
■Vessels / Capacity:5.0ml tube ×6pcs + 1.5ml micro …
Half block for Microtube | B-1120A
Aluminum block for DTU/CTU-Mini/Neo (micro tube 1.5ml x 20)
■Applicable Container / Number:micro tube 1.5ml x …
Half block for Microtube | B-1120B
Aluminum block for DTU/CTU-Mini/Neo (micro tube 2.0ml x 20)
■Applicable Container / Number:micro tube 2.0ml x …
Half block for micro vial | B-1220
Aluminum block for DTU/CTU-Mini/Neo (micro vial 1.5ml x 20)
■Applicable Container / Number:micro vial 1.5ml x …
Half block for disposable centrifuge tube | B-1612L
Aluminum block for DTU/CTU-Mini/Neo (disposable centrifuge tube 15ml x 12)
■Applicable Container / Number:disposable centrifu …
Half block for test tube | B-1712L
Aluminum block for DTU/CTU-Mini/Neo (test tube φ16.5mm x 12)
■Applicable Container / Number:test tube φ16.5mm x …
Half block for Microtube/ PCR plate | B-0696
Aluminum block for DTU/CTU-Neo (micro tube 0.2ml x 96,PCR plate x 1 )
■Applicable Container / Number:micro tube 0.2ml x …
Full block for Microtube | B-1140
Aluminum block for DTU/CTU-Neo (micro tube 1.5ml x 40)
■Applicable Container / Number:micro tube 1.5ml x …