    miniphoto518R


    Enables to measure the absorbance (turbidity) by just inserting Test tube and L-shaped test tube used for cultivation and reaction. Wavelength can be changed with replacement of filter.

    Light shielding cap (Standard accesorie) and Printer (Option) in combination.

    Applications

    Measurement turbidity of Microbe culture fluid
    Absorbance measurement of Colorimetric samples
    Applications requiring measuring Absorbance/Transmittance of sample

    Features

    •For Φ16.5 to 18mm Test tube and L-shaped test tube. Liquid volume 4mL
    •Comes with 660nm Glass filter (Changes wavelength by replacement)
    •Displays the value just inserting test tube. The display can be pinned with HOLD key.
    Compact and lightweight size

    Measurement by inserting Test tube that has been used cultivation and reaction.

    Measure directly in the test tube used for culture
    Minimum volume of the measurement is 4mL .


    Specifications

    Modelminiphoto518R
    Measurement rangeAbsorbance: 0.000 to 2.000A, Transmittance:1-100%T
    Measurementwavelength 660mm (*1)
    VesselsΦ16.5 to 18mm Glass test tube or L-shaped test tube (*2)
    Light source/DetectorHigh-Brightness LED, Photodiode
    DisplayOptical Density/Transmittance simultaneously, HOLD function.
    InterfacePrinter (Option)
    Dimensions (W x D x H)187 x 106 x 95mm
    WeightApporx. 880g
    Power supplyAC100 to 240V
    Standard accessories1 x Glass filter (660nm), 1 x Light shielding cap (*3), 1 x AC adapter
    (*1)Wavelength can be changed with replacement of the filter. See the below option for details. (*2)Test tube without scratches should be used. Ask us when a different diameter of Test tube required.
    (*3)It cannot be used with L shaped test tube. Aluminum foil or something can be substituted if light shielding required.

    Dimensions

    Accessories

    Interference Filter | Interference Filter R420nm
    Band-pass filter approx. 10mm FWHM, R420nm, Dedicated for miniphoto 518R.
    ■: ■:
    Interference Filter | Interference Filter R530nm
    Band-pass filter approx. 10mm FWHM, R530nm, Dedicated for miniphoto 518R.
    ■: ■:
    Interference Filter | Interference Filter R620nm
    Band-pass filter approx. 10mm FWHM, R620nm, Dedicated for miniphoto 518R.
    ■: ■:
    Interference Filter | Interference Filter R660nm
    Band-pass filter approx. 10mm FWHM, R660nm, Dedicated for miniphoto 518R.
    ■: ■: